Biological Safety Cabinets
Choose the right model for your application
SafeFAST Premium – Class II
- Cleanroom class ISO 3 in the work area (according to ISO 14644-1)
- 70 % recirculated air / 30 % exhaust air system via redundant HEPA H14 filters
- Redundant double centrifugal fan (DC) - maximum operational reliability
- Motorised, hinged front panel for easy cleaning & maintenance
- Multifunctional touch display with intuitive control of all parameters
SafeFAST Classic - Class II
- Certified protection in accordance with EN 12469:2000
- Cost-efficient in purchase and operation
- Modularly expandable - for your individual laboratory processes
- Quiet in operation: <53 dB(A) - pleasant in work areas with several devices
- Motorised front screen and manual opening of the front panel using brackets
SafeFAST Compact - Class II
- Compact design - ideal for small laboratories or confined spaces
- Double DC blowers - efficient, safe and energy-saving
- UV LED disinfection - additional hygienic safety
- Ergonomic and quiet - for comfortable and focussed work
- Flexibly configurable - customised to your requirements
SafeFAST Top - Class II
- Maximum safety for user and product
- GMP-compliant stainless steel construction from a single mould
- Particularly easy to clean thanks to seamless design
- Quiet, energy-efficient operation
- Flexible expandability for your specific laboratory requirements
SafeFAST Light - Class II
- Full safety performance despite small width
- EN 12469:2000-compliant - certified protection
- Energy-efficient & quiet - for pleasant working conditions
- Stainless steel interior - hygienic & easy to clean
- Stainless steel rear wall and worktop - hygienic, robust and resistant to chemicals
SafeFAST XXL – Class II
- Large-format work surface - perfect for laboratory robotics and specialised equipment
- H14 HEPA filtration - ISO class 3 air purity
- Configurable according to individual project requirements
- Robust stainless steel construction - also available in full stainless steel (AISI 316)
- DEHS test connections for GMP-compliant filter qualification
SafeFAST Elite - Class II
- TÜV-certified safety in accordance with EN 12469:2000
- Triple protection for product, personnel and environment
- GMP-compliant thanks to stainless steel interior & seamless finish
- Energy-efficient, low-noise and easy to maintain
- Numerous expansion options for individual requirements
SafeFAST Elite - Class I
- 100 % exhaust air operation - no risk due to air recirculation
- Maximum personal protection combined with easy handling
- Certified according to EN 12469:2000
- Low energy consumption and quiet operation
- High-quality materials: stainless steel interior, safety glass, maintenance-friendly filters
SafeFAST Elite - Class II B2
- 100 % exhaust air operation - no air recirculation
- Certified according to NSF/ANSI 49 and EN 12469:2000
- Maximum safety for toxic or volatile substances
- Robust stainless steel construction for a long service life
- Quiet, energy-efficient and easy to maintain
SafeFAST Classic - Class II B2
- Functionality - Class II B2 safety principles
- 100 % exhaust air operation - no air recirculation
- Certified according to NSF/ANSI 49 and EN 12469:2000
- Maximum safety for toxic or volatile substances
- Robust stainless steel construction for a long service life
SafeFAST Elite - Class III
- Fully enclosed design - no contact with ambient air
- Negative pressure operation for maximum contamination safety
- Double H14 HEPA filter system for maximum air purity
- ISO class 3 laminar flow in the working area
- TÜV-certified safety in accordance with EN 12469:2000
CytoFAST Elite / Premium
- Triple protection: personnel, product and environment
- Certified safety in accordance with EN 12469 and DIN 12980
- Modern air guidance system for maximum retention effect
- Maintenance-friendly design with easy filter access
- Flexible configuration for specific requirements and rooms
Biological Safety Cabinets
In modern laboratories, especially in microbiological and biotechnological research and in the pharmaceutical industry, the protection of people, products and the environment is essential. The biological safety cabinets from FASTER offer maximum safety, functionality and ergonomics – developed in accordance with international standards and current GMP guidelines.
Faster’s biological safety cabinets are based on a vertical, unidirectional air flow (laminar flow) in combination with a highly efficient HEPA or ULPA filter system. This creates a contamination-free working environment that reliably protects the product, the personnel and the laboratory environment.
At the same time, the airflow concept fulfils the requirements of cleanroom class ISO 5 in accordance with DIN EN ISO 14644-1 and EU GMP class A in the work area – ideal for sensitive microbiological processes.
Whether for research, diagnostics or production: FASTER offers a comprehensive portfolio of class I, II and III biological safety cabinets. Faster’s standard models are available at short notice and already cover a wide range of applications.
Customised special equipment for special processes:
* Connection options for gases, vacuum or electrics (IP66)
* H2O2 decontamination system (NHP technology)
* Integration of microscopes or scales
* External display connection (HMI, touch, remote access)
* Energy-efficient LED lighting & ergonomic workplace design
Faster’s engineering team will be happy to advise you personally and develop customized solutions with you – tailored precisely to your process requirements and spatial conditions.
Maximum safety and protection – The biological safety cabinets offer optimum protection against contamination. The vertical laminar flow technology ensures that the air is constantly filtered and kept clean. This reliably protects both the samples and the personnel from biological hazards.
Typical Applications
Key Features
Need a configuration tailored to your requirements?
Tell us what you need and our team will help you find the right solution for your cleanroom environment.
Available Models
SafeFAST Premium – Class II
Key Features
- Cleanroom class ISO 3 in the work area (according to ISO 14644-1)
- 70 % recirculated air / 30 % exhaust air system via redundant HEPA H14 filters
- Redundant double centrifugal fan (DC) - maximum operational reliability
- Motorised, hinged front panel for easy cleaning & maintenance
- Multifunctional touch display with intuitive control of all parameters
- Infinitely dimmable LED lighting for glare-free, eye-friendly working
- Segmented work surface made of stainless steel AISI 1.4301 or 1.4404 - hygienic & easy to clean
- Side panes made of safety glass with 3 integrated media connections per side (19 mm)
- Two 230 V sockets integrated in the interior as standard
- GMP-compliant design & IQ/OQ documentation on request
Applications
- Microbiology
- virology
- haematology
- Cell cultures
- Genetics
SafeFAST Classic - Class II
Key Features
- Certified protection in accordance with EN 12469:2000
- Cost-efficient in purchase and operation
- Modularly expandable - for your individual laboratory processes
- Quiet in operation: <53 dB(A) - pleasant in work areas with several devices
- Motorised front screen and manual opening of the front panel using brackets
- Side windows: Made from robust safety glass
- Segmented work surface: Made of stainless steel, easy to remove and clean
- 70 % of the air is recirculated via an H14 HEPA main filter in accordance with EN 1822
- 30 % of the air is discharged from the appliance in a controlled manner via a separate H14 HEPA exhaust air filter
Applications
- Microbiology and virology
- Cell culture techniques and molecular biology procedures
- Haematology and blood analysis
- Genetics, PCR workstations, DNA/RNA handling
- GMP-compliant drug production and quality control
SafeFAST Compact - Class II
Key Features
- Compact design - ideal for small laboratories or confined spaces
- Double DC blowers - efficient, safe and energy-saving
- UV LED disinfection - additional hygienic safety
- Ergonomic and quiet - for comfortable and focussed work
- Flexibly configurable - customised to your requirements
- Robust materials - durable and easy to clean
- Optionally with gas spring-supported front screen for improved access
Applications
- Routine microbiological testing
- Cell culture and tissue laboratories
- Molecular biology research
- Pharmaceutical quality control
- Biotechnology start-ups or mobile laboratories
- University and training laboratories with limited space
SafeFAST Top - Class II
Key Features
- Maximum safety for user and product
- GMP-compliant stainless steel construction from a single mould
- Particularly easy to clean thanks to seamless design
- Quiet, energy-efficient operation
- Flexible expandability for your specific laboratory requirements
- Hinged front panel for easy access and hygienic cleaning
- 1x vacuum connection, permanently integrated
- 1x gas tap with safety solenoid valve - automatic switch-off when inactive
- 2x socket, integrated as standard
- Expandable media connections & electrics
Applications
- Microbiology - bacterial, mould and yeast cultures
- Virology - working with infectious viruses or samples
- Haematology - blood analysis and cell examination
- Cell culture - cultivation and manipulation of cell lines
- Molecular biology & genetics - DNA/RNA isolation, PCR preparation
- GMP-compliant production - for pharmaceutical and biotechnological processes
SafeFAST Light - Class II
Key Features
- Full safety performance despite small width
- EN 12469:2000-compliant - certified protection
- Energy-efficient & quiet - for pleasant working conditions
- Stainless steel interior - hygienic & easy to clean
- Stainless steel rear wall and worktop - hygienic, robust and resistant to chemicals
- Side panes made of shatterproof safety glass
- Multifunctional display - intuitive operation, display of operating parameters and alarm functions
- 1 integrated socket (230 V) for connecting laboratory equipment
Applications
- Microbiology
- Virology
- Haematology
- Cell culture
- Molecular biology and genetics
- Small production areas (e.g. pharmacies)
- Diagnostics and research laboratories with limited space
SafeFAST XXL – Class II
Key Features
- Large-format work surface - perfect for laboratory robotics and specialised equipment
- H14 HEPA filtration - ISO class 3 air purity
- Configurable according to individual project requirements
- Robust stainless steel construction - also available in full stainless steel (AISI 316)
- DEHS test connections for GMP-compliant filter qualification
- Suitable for GMP & ISO certified production areas
- Reinforced work surface made of AISI 316L stainless steel- Alternatively: perforated version or closed work tray
- Microprocessor control with visual & acoustic alarms for all safety-relevant parameters
- LED lighting outside the laminar airflow - bright, glare-free and low-maintenance
- Quick couplings for DEHS filter integrity tests - for easy qualification
- Negative pressure operation guarantees that no contamination can escape from the interior
Applications
- Automated laboratory processes with robotic systems
- Integration of 3D printers and bioprinting technologies
- Working with large-volume cell culture or liquid manipulation systems
- High-throughput screening platforms
- Pharmaceutical and biotechnological production lines
- Projects with customised laboratory space and safety requirements
SafeFAST Elite - Class II
Key Features
- TÜV-certified safety in accordance with EN 12469:2000
- Triple protection for product, personnel and environment
- GMP-compliant thanks to stainless steel interior & seamless finish
- Energy-efficient, low-noise and easy to maintain
- Numerous expansion options for individual requirements
- Motorised, fully hinged front window
- 2-3 integrated sockets (230 V), depending on the appliance size
- Side panes each with 3 integrated media connections (diameter 19 mm) for air, gas or vacuum
- Multifunctional display with user guidance, alarm management and operating data display
Applications
- Microbiology & Virology
- Cell culture & molecular biology
- Haematology & genetics
- Quality control in pharmaceutical and biotech companies
- Pharmacies, research institutes, universities
SafeFAST Elite - Class I
Key Features
- 100 % exhaust air operation - no risk due to air recirculation
- Maximum personal protection combined with easy handling
- Certified according to EN 12469:2000
- Low energy consumption and quiet operation
- High-quality materials: stainless steel interior, safety glass, maintenance-friendly filters
- Ideal for smaller laboratories, medical practices, diagnostic centres and research institutes
- Interior made of high-quality stainless steel (AISI 304): Hygienic, corrosion-resistant and durable
- Segmented stainless steel work surface - easy to remove and clean
- Multifunctional display: Monitoring and control of central parameters such as air flow, filter status, maintenance instructions
Applications
- Microbiology: Processing of potentially infectious samples
- Virology: diagnostics of viral diseases
- Haematology & serology: handling blood samples
- Cell cultures: When sterility of the product is not required
- Molecular biology & genetics: Working with DNA/RNA under safe conditions
SafeFAST Elite - Class II B2
Key Features
- 100 % exhaust air operation - no air recirculation
- Certified according to NSF/ANSI 49 and EN 12469:2000
- Maximum safety for toxic or volatile substances
- Robust stainless steel construction for a long service life
- Quiet, energy-efficient and easy to maintain
- Extensive equipment options for individual requirements
- Interior work surface made of stainless steel 1.4404 / AISI 316LRear wall stainless steel 1.4301 / AISI 304
Applications
- Microbiological and virological research
- Cell and tissue cultures
- Haematology and molecular genetic analysis
- Working with cytostatics, DNA extractions or radioactive substances
- Pharmaceutical quality control under GMP conditions
- Safety level S2 and higher (in conjunction with suitable exhaust air technology)
SafeFAST Classic - Class II B2
Key Features
- Functionality - Class II B2 safety principles
- 100 % exhaust air operation - no air recirculation
- Certified according to NSF/ANSI 49 and EN 12469:2000
- Maximum safety for toxic or volatile substances
- Robust stainless steel construction for a long service life
- Extensive equipment options for individual requirements
Applications
- Microbiological and virological research
- Cell and tissue cultures
- Haematology and molecular genetic analysis
- Working with cytostatics, DNA extractions or radioactive substances
- Pharmaceutical quality control under GMP conditions
- Safety level S2 and higher (in conjunction with suitable exhaust air technology)
SafeFAST Elite - Class III
Key Features
- Fully enclosed design - no contact with ambient air
- Negative pressure operation for maximum contamination safety
- Double H14 HEPA filter system for maximum air purity
- ISO class 3 laminar flow in the working area
- TÜV-certified safety in accordance with EN 12469:2000
- Can be customised to meet your specific requirements
Applications
- High security laboratories (BSL-3 / BSL-4)
- Central diagnostic laboratories with high-risk samples
- Research facilities with high-risk pathogens
- Pharmaceutical development of toxic substances
- Biotechnological production areas with viral vectors or cell therapies
CytoFAST Elite / Premium
Key Features
- Triple protection: personnel, product and environment
- Certified safety in accordance with EN 12469 and DIN 12980
- Modern air guidance system for maximum retention effect
- Maintenance-friendly design with easy filter access
- Flexible configuration for specific requirements and rooms
- Ergonomic design for comfortable, safe working
Applications
- Pharmacies & hospital laboratories: Preparation of chemotherapy and CMR drugs
- Oncological research: Safe handling of toxic substances
- Pharmaceutical industry: Production and testing of highly effective active ingredients
- Biotechnology & cell culture: Working with sample material at risk of contamination
- GMP-compliant production environments with high safety requirements
Technical information and documentation
Additional technical information and original manufacturer documentation are available through the source links below.